SG Ground Truth

POST /schema/<Type>/fields

post_schema_type_fields

You send a display name and the server derives the sg_ name, which is only in links.self. A duplicate display name is 201 with a silent _1 suffix, so read /fields first.

API

Params

part value
data_type the type. text float number date date_time list url duration percent footage take nothing else
properties a list of {property_name, value}. name is the display name
valid_types required for entity and multi_entity, and exactly one element
default_value required for checkbox

Sample requests

r = c.post("/schema/Version/fields",
           json={"data_type": "text",
                 "properties": [{"property_name": "name", "value": "zzprobe 019 With (Parens)"}]})

The programmatic name is not in the body. It is the last segment of links.self:

{
  "data":  { "name": { "value": "zzprobe 019 With (Parens)" }, "data_type": { "value": "text" } },
  "links": { "self": "/api/v1/schema/Version/fields/sg_zzprobe_019_with__parens_" }
}

An entity field, where properties is not optional:

r = c.post("/schema/Version/fields",
           json={"data_type": "entity",
                 "properties": [{"property_name": "name", "value": "Source Plate"},
                                {"property_name": "valid_types", "value": ["Shot"]}]})
{"errors": [{"status": 400, "code": 103,
             "title": "'valid_types' value expected Array with one element"}]}

That error is what two or more types answers. One element is 201.

Response codes

status when
201 created
400 {"data_type": ["data_type is not valid"]} for color and image
400 'valid_types' value expected Array with one element for two or more
400 schema_field_create() failed, there is a retired field with the same field_name
500 bare checkbox, Only true or false allowed in checkbox
500 calculated, NoMethodError

Edge cases

Display name to programmatic name, measured:

display name sent name created
zzprobe 019 With (Parens) sg_zzprobe_019_with__parens_
sg_zzprobe_019_already_prefixed sg_sg_zzprobe_019_already_prefixed, prefixed twice
a name already in use <name>_1, at 201, with no warning
  • Deleting a field does not free its name. DELETE retires the field and the name stays taken, released only by emptying the Trash page in the web interface. An ensure() reads /fields first rather than posting and hoping, and a field created to test with is named sg_zzprobe_<nnn>_* so whoever empties that page can tell litter from a real field.
  • number takes 2147483647 and 400s on 2**63, so a 64-bit id or seed does not fit one.

Every entry on this site is the output of a probe in probes/. The corpus is generated by running those probes against a live Flow Production Tracking site, not written from memory.